翻訳と辞書
Words near each other
・ Sanger Unified School District
・ Sanger Union High School
・ Sanger, California
・ Sanger, North Dakota
・ Sanger, Texas
・ Sanger, West Virginia
・ Sanger-Harris
・ Sanger-Harris Building
・ Sangerfield, New York
・ Sangerhausen
・ Sangerhausen (district)
・ Sangerman's Bombers
・ Sangertown Square
・ Sangerville Town Hall
・ Sangerville, Maine
Sanger–Black apparatus
・ Sangestan
・ Sangestan Rural District
・ Sangestan, Golestan
・ Sangestan, Hamadan
・ Sangestan, Kerman
・ Sangestan, Markazi
・ Sangestar Tso
・ Sangfor Technologies
・ Sangfroid
・ Sanggai Chanu
・ Sanggal Station
・ Sanggamnyong
・ Sanggan River
・ Sanggar Agung


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Sanger–Black apparatus : ウィキペディア英語版
Sanger–Black apparatus

Sanger–Black apparatus〔Ch. R. Sanger and O. F. Black. The Quantitative Determination of Arsenic by the Gutzeit Method. ''Proc. Am. Acad. Arts Sci''. 1907, ''43'' (''8''), 297–325. On the Web: http://www.unz.org/Pub/Daedalus-1907q1-00295〕 is a piece of chemical laboratory ware used for quantitative and semi-quantitative determination of arsenic element in the solution. It is constituted by glass bottle of volume ca. 30 mL, sealed with rubber stopper with one or two holes. Through one hole a thistle tube is inserted, almost reaching the bottom, for filling the bottle (what can be done also when the stopper is taken out – for semi-quantitative determination). The second, S-shaped tube is for outflow of the gases and joined by another rubber stopper to a bulg tube, with bulb containing pre-dried cotton as adsorbent, presumably intended for homogenizing the gas flow. A thin reagent paper, impregnated with mercury(II) chloride (nowadays replaced by mercury(II) bromide)〔Kinniburgh, D. G. Kosmus, W. ''Talanta'' 2002, ''58 (1)'', 165–180.〕 or silver(I) nitrate, is placed in the open end of the bulb tube. If the semi-quantitative variant is to be performed, the paper is put in the (only) thistle tube – i. e., vertically, not horizontally. During the test ca. 3 g of Zn granules are placed into the bottle, just below the end of thistle tube, and then acid solution is added (ca. 15 mL; authors recommend that HCl is preferable to H2SO4). About 10 minutes are required to let H2 flow along the reagent paper, while this flow and moisture content inside it is stabilizing. Then the sample is introduced, and in case of sample solution containing arsenic the paper becomes more or less stained.〔
The Sanger–Black determination is based on the so-called ''Gutzeit'' reaction (1879):〔〔Gutzeit, H. ''Pharmaz. Zeitung''. 1879, ''24'', p. 263〕
AsH3 is forming from arsenic in any oxidation state when it reduces with the hydrogen ''in statu nascendi'', produced from the acid.〔〔Gutzeit test – Medical Definition and More from Merriam–Webster. On the Web: http://www.merriam-webster.com/medical/gutzeit%20test〕 Gutzeit originally used AgNO3 for determination.〔 The innovation to the Gutzeit method by Sanger and Black is the use of long and narrow paper, so that gas flow is directed along it and the product of reaction used as analytic signal deposits almost uniquely in the surface layers of the paper, so that stain area is quantitative analytic signal (if all the prerequisities for determination are fulfilled).〔 Unfortunately, yellow colour is not that human eye is especially sensitive for, so photometric tools were introduced for quantitative analysis quite a long time ago (in 1944).〔〔Satterlee, H. S. Blodgett, G. ''Ind. Eng. Chem.'' 1944, ''16'', p. 400〕
It should be noted that zinc naturally contains some trace amounts of arsenic,〔 so a modest yellow stain appears almost in any case on the reagent paper. This limits the sensitivity of this test, as arsenic amounts in zinc vary from one supplier to another. That is why later Zn was replaced by sodium borohydride NaBH4; then, strong and corrosive hydrochloric acid was also replaced with sulfamic acid NH2SO3H.〔
== Sources ==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Sanger–Black apparatus」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.